The classic 1.5T Magnetic Resonance Magneto Avanto has been installed in over 3000 units worldwide since its launch, creating a legend for Siemens Magnetic Resonance.
As the first device equipped with Tim (Total Imaging Matrix) technology, Avanto has always been a representative of advanced magnetic resonance imaging in the industry through its ultra-high quality and wide range flexible imaging.
Brand new hardware design:
The Zhiduoxing platform provides specialized shimming technology for special sequences or regions that require high magnetic field uniformity, such as the neck and heart, through over 50 sets of active shimming coils, significantly reducing image artifacts caused by local magnetic field non-uniformity.
Efficient workflow
The Zhiduoxing platform covers the entire workflow from patient preparation stage (including automatic coil ion, automatic scanning positioning), to image acquisition stage (automatic registration and positioning of layers, automatic optimization of parameter settings, automatic patient instructions, and automatic detection technology of contrast agents, etc.), and finally to automatic image processing to obtain standardized, stable, and excellent diagnostic images and other magnetic resonance examinations. While greatly accelerating the scanning speed, it ensures the accuracy and high consistency of the imaging results.
More accurate imaging
Both local and large-scale inspections are covered by high-density coil units, which can achieve higher image signal-to-noise ratio and spatial resolution.
Scan more flexibly
When scanning, only the examination site needs to be ed, no longer limited by coil size. Through the flexible combination of surface matrix coils, complex clinical examination needs can be met.
Faster inspection
Through the flexible combination of coils, all inspections can be completed in one go without the need for repeated coil replacement, saving unnecessary time and having an efficient scanning process, thus achieving fast inspection speed.
Mature zero liquid helium technology
Under normal use, Avanto does not require liquid helium filling throughout its entire lifecycle, saving a significant amount of equipment costs and allowing users to have no worries.
Excellent magnet uniformity
High quality magnets ensure uniformity, and the typical value of magnetic field uniformity within a 50cm range is about 0.8ppm measured by accurate 24 plane point method.
Short magnet technology leading the trend
Avanto's magnet length is only 1.5m, which greatly ensures patient comfort while reducing the site requirements for equipment installation. The overall installation area is less than 30 square meters.
Fast, high-resolution large-scale imaging
Tim technology uses high-density surface coil combinations to complete large-scale scans in one go. More conducive to diagnosing metastatic diseases and possessing strong ability to capture small lesions.
Easily achieve large field of view imaging
Avanto's stable magnets provide excellent image quality and uniformity even at maximum FOV.